Product Category

OMNIS Mystery Generation Karl Fischer Moisture Analyzer

  • Category :
    instrument
  • Browse number : ...
  • Release time : 2024-05-28
  • Detailed Description

OMNIS Mystery Generation Karl Fischer Moisture Analyzer
Switzerland's Wantong Redefining the Karl Fischer Moisture Meter with Capacity Method: Discovering the Mysteries of OMNIS Generation 1

OMNIS's first generation volumetric Karl Fischer moisture analyzer is a very new overall solution for moisture measurement by Swiss company Wantong. It makes the detection of moisture in samples more convenient, safe, and simple.

Safety: All chemicals are processed in a closed system without the need for contact with reagents

Simple: Automatically start measuring moisture content when the sample is injected

Convenient: Automatically add Karl Fischer reagent and discharge waste liquid

Fast: OMNIS Mystery Generation Karl Fischer Moisture Analyzer makes sample pre-treatment simple and fast

Safe OMNIS Mystery Generation Karl Fischer Moisture Analyzer

OMNIS Mystery Generation makes Karl Fischer moisture measurement safer. Exposure to toxic reagents and solvents is eliminated:

3S liquid adapter technology enables contactless reagent replacement

All reagents are in a closed system

Used reagents are automatically discharged

Automatic addition and emptying of titration tanks

Simple OMNIS Mystery Generation Karl Fischer Moisture Analyzer

OMNIS Mystery Generation makes volumetric Karl Fischer moisture measurement simpler. This system takes on many tasks that originally required manual operation from you:

Automatically start titration

After measurement, the used samples will be automatically discharged

The titration cell automatically prepares for the next measurement

Quick OMNIS Mystery Generation Karl Fischer Moisture Analyzer: Remove lid - Titrate - Close lid - Repeat - Automatically complete all steps

 

The automated OMNIS mystery generation makes your laboratory work seamless.

By configuring your OMNIS Mystery Generation Karl Fischer moisture analyzer with a robot sample processor, the system achieves 100% automation - all you need to do is place the samples in an orderly manner and press the start button.

The system will fully automate the analysis process, including opening and closing the sample cup lid.

Simple and fast sample pretreatment (can save 25% of time)

Protect the sample from environmental factors

KF Dis Cover Automatic Cover Opening Design

Parallel workstation (40% faster than sequential measurement)

More highlights of the OMNIS Mystery Generation Analysis Platform

◆ Better user experience: OMNIS Mystery Generation software

The OMNIS Mystery Generation Analysis Platform is based on innovative and intuitive software. Enhance your user experience through software features such as prompt language, embedded help, system verification, and status indicators.

Upgrade your system as needed: add modules and features

OMNIS Mystery Generation can freely expand your system according to your needs. Starting from a titrator, you can precisely add a dispensing module, titration module, and robot sample processor as needed

More samples? Simple upgrade

Starting from the OMNIS Mystery Generation Robot Sample Processor with one workstation, simply add another workstation to your existing system to greatly increase your sample throughput.

The four parallel workstation system will help you save up to 60% of time compared to a single workstation system.

What is a volumetric Karl Fischer moisture meter?

The Karl Fischer titration method is a classic method for moisture determination. Compared with other methods, the Karl Fischer titration method determines the actual moisture content in the sample,

Instead of using methods such as oven drying or infrared lamps, it measures the content of all volatile substances in the sample after heating.

One major advantage of the Karl Fischer titration method compared to the oven drying method, which takes several hours, is that it takes less time, only a few minutes.

Karl Fischer titration is a recognized and widely used analytical method. For example, it is listed as a reference method in domestic and international standards across various industries.

Core parameters:

Titration method: fully automatic titration

Instrument type: Capacity based Karl Fischer moisture meter

Origin category: Imported

Measurement resolution: N/A

Moisture content measurement range: -2400...+2400 mV

Measurement resolution: 0.1 mv

Measurement accuracy: ± 3 μ g (10 μ g~1000 μ g); ≤ 0.3% (>1000 μ g)

Minimum feed rate: 10 μ g

Titration control accuracy: N/A